Cummins fault 3429 troubleshooting manual — Code 3429 — PDF, 13

This Cummins fault 3429 document is a troubleshooting manual for the aftertreatment diesel exhaust fluid line heater 4 circuit. It explains the current below normal or open circuit fault, the amber lamp response, torque reduction risk, and the INSITE™ checks used to validate repair. The file is Code 3429.pdf, supplied as a 13-page English PDF.

Official Cummins fault 3429 document details

Brand Cummins
Model coverage ISB6.7 CM2250 (2010-12); extract also references ISX11.9 CM2250, ISC8.3 and ISL9 CM2250, and ISX15 CM2250
System/Group DTCs; Aftertreatment Diesel Exhaust Fluid Line Heater 4 Circuit
Publication no. Not specified in this file extract
Year/Revision Last Modified: 11-Jun-2010
Pages 13
File size 0.2 MB
Format PDF
Language English

Document table of contents

  • Overview
  • Circuit Description
  • Component Location
  • Conditions for Running the Diagnostics
  • Conditions for Setting the Fault Codes
  • Action Taken When the Fault Code is Active
  • Conditions for Clearing the Fault Code
  • Shop Talk
  • Associated Procedures
  • Troubleshooting Steps
  • Guided Step 1 – Check the fault codes.
  • Guided Step 2 – Check the aftertreatment diesel exhaust fluid line heater 4 and circuit.
  • Guided Step 3 – Check the aftertreatment diesel exhaust fluid controller and harness.
  • Guided Step 4 – Check ECM calibration and clear fault codes.

Applicable truck models

This manual applies to Cummins aftertreatment diagnostics for the ISB6.7 CM2250 group listed in the file information. The extract also names ISX11.9 CM2250, ISC8.3 and ISL9 CM2250, and ISX15 CM2250 in the fault-code header and associated procedure table. It covers Fault Code 3429, SPN 4346, FMI 5, where the aftertreatment diesel exhaust fluid controller detects an open circuit or short to ground in diesel exhaust fluid line heater 4. The line heater is internal to the aftertreatment diesel exhaust fluid dosing unit and cannot be serviced separately. Official manufacturer information is available from Cummins.

Who needs this Cummins fault 3429 manual

Workshop technicians, fleet mechanics, and diagnostic tool users need this Cummins fault 3429 manual when an amber CHECK ENGINE lamp or MIL is linked to DEF line heater 4 current below normal. It is useful when inspecting dosing unit connector pins, testing the controller harness supply and signal circuits, checking resistance limits, reviewing ECM calibration, and clearing the fault with INSITE™ electronic service tool.

The full PDF is available in the DiagTechPro manuals library, free account required to download.

Related manuals library

Cummins fault 3429 troubleshooting manual — Code 3429 — PDF, 13 1 / 3
Cummins fault 3429 troubleshooting manual — Code 3429 — PDF, 13 - preview page 1 of 3
Cummins fault 3429 troubleshooting manual — Code 3429 — PDF, 13 - preview page 2 of 3
Cummins fault 3429 troubleshooting manual — Code 3429 — PDF, 13 - page 3 is available after signing in
Free preview - 2 of 3 pages. Sign in to download the full PDF. Create a free account to download the full PDFNo credit card required · Instant download

Sản phẩm liên quan cho hãng này

Cùng brand theo taxonomy hiện có trong catalog WooCommerce.

This entry was posted in . Bookmark the permalink.
Telegram Telegram us WhatsApp WhatsApp us