Cummins ISX11.9 code 319: Real-Time Clock Power Interrupt (SPN

Cummins ISX11.9 code 319 is the Cummins diagnostic trouble code covering real-time clock power interrupt – data erratic, intermittent, or incorrect on ISX11.9 and ISX12 CM2250 engines. This DiagTechPro reference summarises what the fault code 319 troubleshooting document contains, so a technician can confirm the problem before opening the full procedure and starting a repair.

What Cummins ISX11.9 code 319 means

Fault code 319 is logged by the engine control module (ECM) and reported as SPN 251 with FMI 2 (PID P251). Cummins records describe the condition as: Real-Time Clock Power Interrupt – Data Erratic, Intermittent, or Incorrect. When it sets, the ECM commands the maintenance warning lamp so the driver and workshop are alerted to the issue.

Fault code details

Fault code 319
SPN 251
FMI 2
PID P251
Warning lamp Maintenance
Applies to ISX11.9 CM2250 and ISX12 CM2250 (2010-12)

Circuit and component location

The real-time clock battery is secured to the engine harness near the ECM. Knowing where the part sits matters, because many false readings on this circuit come from harness chafing, corroded connector pins, or moisture in the OEM wiring rather than a failed component.

Diagnostic and repair overview

The document follows the standard Cummins flow: verify the complaint, read active and inactive codes, then work through the circuit checks in order. Typical steps include:

  • Confirm fault code 319 is active with the Cummins INSITE electronic service tool.
  • Inspect the real-time clock power interrupt circuit, its connectors, and the OEM harness for damage.
  • Measure signal, supply, and return voltages against the published specifications.
  • Repair or replace the faulty part, then run the engine to validate the repair.

For manufacturer background on the engine platform and its service network, see Cummins official support. You can also browse the full DiagTechPro manuals library for more ISX11.9 CM2250 material.

About this Cummins ISX11.9 code 319 manual

This page is based on the Cummins ISX11.9 and ISX12 CM2250 fault code troubleshooting information used with the Cummins INSITE service tool. Always match SPN 251 and FMI 2 against the vehicle before condemning parts, and follow the printed wiring and torque specifications exactly.

Cummins ISX11.9 code 319: Real-Time Clock Power Interrupt (SPN 1 / 6
Cummins ISX11.9 code 319: Real-Time Clock Power Interrupt (SPN - preview page 1 of 6
Cummins ISX11.9 code 319: Real-Time Clock Power Interrupt (SPN - preview page 2 of 6
Cummins ISX11.9 code 319: Real-Time Clock Power Interrupt (SPN - page 3 is available after signing in
Free preview - 2 of 6 pages. Sign in to download the full PDF. Create a free account to download the full PDFNo credit card required · Instant download

Sản phẩm liên quan cho hãng này

Cùng brand theo taxonomy hiện có trong catalog WooCommerce.

This entry was posted in . Bookmark the permalink.
Telegram Telegram us WhatsApp WhatsApp us