Cummins fault code 1969 — ISM CM871 (2007-09) DTC manual — SPN

Cummins fault code 1969 is documented on this DiagTechPro library page for Cummins ISM CM871 (2007-09) engines, where it flags the Aftertreatment Exhaust Gas Temperature 2 – Data Valid but Above Normal Operational Range – Most Severe Level condition (PID S327, SPN 3249, FMI 0/0, Red lamp). This 4-page PDF reproduces the manufacturer description, shop talk, component location and step-by-step troubleshooting so technicians can confirm and clear the code.

Cummins fault code 1969 overview

Cummins identifies this code as “Aftertreatment Exhaust Gas Temperature 2 – Data Valid but Above Normal Operational Range – Most Severe Level” on the Aftertreatment Temperature Sensors. The aftertreatment temperature sensors are used by the electronic control module (ECM) to monitor the engine exhaust temperatures in the aftertreatment system. The aftertreatment temperature sensors are thermistors and change resistance based on the temperature being measured. The ECM provides a 5 volt reference voltage to the sensor. The ECM monitors the change in signal voltage and converts this to a temperature value. When the exhaust temperature is cold, the sensor or thermistor resistance is high. The ECM signal voltage only pulls down a small amount through the sensor to ground. Therefore, the ECM senses a high signal voltage or low temperature.

According to the shop talk notes, possible causes include:

  • A damaged fuel injector causing unburned fuel to enter the exhaust system.
  • A damaged aftertreatment fuel injector.

Official document details

Brand Cummins
Model coverage Cummins ISM CM871 (2007-09); Cummins ISX CM871 (2007-09)
System / Group Aftertreatment Temperature Sensors — ISM CM871 fault codes
Fault code 1969 (SPN 3249, FMI 0/0)
PID S327
Warning lamp Red
Source TruckFaultCodes.com Cummins fault code reference (© 2017)
Pages 4
File size 0.2 MB
Format PDF
Language English

Document table of contents

  • Fault code identification (PID, SPN, FMI, lamp)
  • Description
  • Shop Talk
  • Component Location
  • Troubleshooting Steps

Applicable truck models and engines

This document applies to Cummins ISM CM871 (2007-09); Cummins ISX CM871 (2007-09) equipped diesel engines that log Fault Code 1969. Always confirm engine calibration and use a Cummins diagnostic tool such as INSITE to read live data before replacing parts. Full specifications are published on the Cummins official website.

Who needs this Cummins fault code 1969 manual

Heavy-duty truck technicians, fleet workshops and owner-operators diagnosing an electronic control module warning on ISM CM871 engines use this sheet to verify the fault before parts are replaced.

The full PDF is available in the DiagTechPro manuals library; a free account is required to download.

Cummins fault code 1969 — ISM CM871 (2007-09) DTC manual — SPN 1 / 4
Cummins fault code 1969 — ISM CM871 (2007-09) DTC manual — SPN - preview page 1 of 4
Cummins fault code 1969 — ISM CM871 (2007-09) DTC manual — SPN - preview page 2 of 4
Cummins fault code 1969 — ISM CM871 (2007-09) DTC manual — SPN - page 3 is available after signing in
Free preview - 2 of 4 pages. Sign in to download the full PDF. Create a free account to download the full PDFNo credit card required · Instant download

Sản phẩm liên quan cho hãng này

Cùng brand theo taxonomy hiện có trong catalog WooCommerce.

This entry was posted in . Bookmark the permalink.
Telegram Telegram us WhatsApp WhatsApp us