Start Enable Relay — Eaton Fault Code 17, TRTS0980 Fault – Guide

Start Enable Relay faults set Eaton Fault Code 17 on the Fuller Advantage Heavy Duty transmission, whose neutral-crank logic prevents the engine cranking unless the transmission confirms neutral. This five-page section of publication TRTS0980 defines the J1939 SPN 1321 FMI 3, 4 and 14 conditions, explains the latch coil, voltage and ground supply, and lists the wiring and bypass causes. It also shows the four normally open circuit states used when diagnosing a no-crank complaint.

Official document details

Brand Eaton
Model coverage Fuller Advantage & Fuller Advantage Heavy Duty automated transmission
System / Group DTCs – Fault Isolation Procedures
Publication no. TRTS0980
Year / Revision 2016 (Rev. 2016.06.20)
Pages 5
File size 0.7 MB
Format PDF
Language English

Start Enable Relay table of contents

  • Overview and fault description
  • Detection method
  • Conditions to set the fault code active
  • Fallback and dashboard symptoms
  • Conditions to set the fault code inactive
  • Possible causes
  • Component identification
  • Relay circuit states (normally open)

Applicable truck models covered

This definition covers Eaton Fuller Advantage and Fuller Advantage Heavy Duty automated transmissions on chassis that use a physical relay rather than J1939 crank enable messaging. The relay circuit is supplied and wired by the OEM through the 5-Way socket and 38-Way Vehicle Harness, so OEM schematics are required. Transmission data is published on the manufacturer’s official Eaton transmissions website.

Who needs this Start Enable Relay manual

Truck electricians diagnosing a no-crank complaint use this Enable Relay reference to confirm neutral logic, coil latching and OEM wiring before condemning the relay or the TECU. The four circuit-state diagrams show exactly when the relay should be open or closed for key-on and key-start, which makes it easier to judge a live reading against the intended behaviour.

The complete PDF, published under Eaton document TRTS0980, is available in the DiagTechPro manuals library; a free account is required to download it.

Start Enable Relay — Eaton Fault Code 17, TRTS0980 Fault – Guide 1 / 5
Start Enable Relay — Eaton Fault Code 17, TRTS0980 Fault – Guide - preview page 1 of 5
Start Enable Relay — Eaton Fault Code 17, TRTS0980 Fault – Guide - preview page 2 of 5
Start Enable Relay — Eaton Fault Code 17, TRTS0980 Fault – Guide - page 3 is available after signing in
Free preview - 2 of 5 pages. Sign in to download the full PDF. Create a free account to download the full PDFNo credit card required · Instant download
Telegram Telegram us WhatsApp WhatsApp us