Cummins fault code 1877 Troubleshooting Manual — Code 1877 — PDF,

This Cummins fault code 1877 document is a troubleshooting PDF for the aftertreatment diesel particulate filter outlet temperature sensor circuit. It explains the circuit description, fault code logic, diagnostic conditions, guided checks, OEM harness tests, sensor replacement decision points, and INSITE™ fault-code clearing steps.

Official Cummins fault code 1877 document details

Brand Cummins
Model coverage ISB6.7 CM2150 (2007-09); extract also references ISB, ISC, and ISL with CM2150
System/Group DTCs; Aftertreatment Temperature Sensors
Publication no. Not shown in the extract
Year/Revision Last Modified: 20-Jul-2010
Pages 12
File size 0.3 MB
Format PDF
Language English

Document table of contents

  • Overview
  • Circuit Description
  • Component Location
  • FAULT CODE 1877
  • Conditions for Running the Diagnostics
  • Conditions for Setting the Fault Codes
  • Action Taken When the Fault Code is Active
  • Conditions for Clearing the Fault Code
  • Shop Talk
  • Associated Procedures
  • Troubleshooting Steps
  • Guided Step 1 – Check the fault codes.
  • Guided Step 2 – Check the aftertreatment diesel particulate filter outlet temperature sensor and circuit.
  • Guided Step 3 – Check the ECM and OEM harness.
  • Guided Step 4 – Clear the fault codes.

Applicable truck models

This file applies to Cummins ISB6.7 CM2150 (2007-09) DTC troubleshooting and references ISB, ISC, and ISL engines with CM2150 aftertreatment temperature sensors. The component covered is the aftertreatment diesel particulate filter outlet temperature sensor, also identified in the fault text as Aftertreatment Exhaust Gas Temperature 3 Circuit, with SPN 3245 and FMI 4/4. For official product and service information, visit Cummins.

Who needs this Cummins fault code 1877 manual

Workshop owners, diesel mechanics, and fleet technicians need this fault code 1877 manual when an amber CHECK ENGINE light is active and regeneration is disabled because the ECM detects low signal voltage below 0.1-VDC for more than 2 seconds. The procedure supports connector inspection, sensor circuit response checks, resistance measurements above 100k ohms, and decisions to repair the OEM Wiring Harness, replace the Aftertreatment Exhaust Gas Temperature Sensor, or request ECM replacement authorization.

The full PDF is available in the DiagTechPro manuals library, free account required to download.

Related manuals library

Cummins fault code 1877 Troubleshooting Manual — Code 1877 — PDF, 1 / 3
Cummins fault code 1877 Troubleshooting Manual — Code 1877 — PDF, - preview page 1 of 3
Cummins fault code 1877 Troubleshooting Manual — Code 1877 — PDF, - preview page 2 of 3
Cummins fault code 1877 Troubleshooting Manual — Code 1877 — PDF, - page 3 is available after signing in
Free preview - 2 of 3 pages. Sign in to download the full PDF. Create a free account to download the full PDFNo credit card required · Instant download

Sản phẩm liên quan cho hãng này

Cùng brand theo taxonomy hiện có trong catalog WooCommerce.