3242 FMI 3 EPA07 — DOC Inlet Temperature Circuit Failed High

3242 FMI 3 EPA07 is the Detroit DD Series fault-code procedure for a diesel oxidation catalyst inlet temperature circuit failed-high fault. This 3-page diagnostic PDF documents the fault, its monitored circuit on the diesel oxidation catalyst (DOC) inlet temperature sensor, and the exact troubleshooting steps a technician follows to confirm and repair the failure.

Official document details

Brand Detroit
Model coverage DD Series (EPA 2007-Current); Series 60 DDEC VI
System / Group DD Series / DTCs
SPN (fault code) 3242
FMI (failure mode) 3
Emission family EPA07 calibration
Source Detroit Power Service Literature (Copyright © 2017)
Pages 3
File size 0.26 MB
Format PDF
Language English

Document table of contents

  • Fault code identification (fault 3242, failure mode 3)
  • Troubleshooting steps
  • Multiple-code check and turbocharger inlet air sensor
  • DOC inlet sensor resistance and voltage checks

Applicable truck models

This procedure applies to Detroit DD13, DD15 and DD16 engines in the DD Series (EPA 2007-Current) range and the equivalent Series 60 (DDEC VI) platform, as fitted to Freightliner and Western Star trucks. Confirm the EPA07 emission family matches the truck before following the steps; full model and coverage data is published on the Detroit official website.

Who needs this 3242 FMI 3 EPA07 manual

Diesel technicians, fleet workshops and mobile mechanics diagnosing a DOC inlet temperature circuit failed-high code on EPA07 Detroit engines need this reference to test the circuit correctly with a diesel diagnostic tool instead of replacing parts by guesswork.

3242 FMI 3 EPA07 repair steps explained

Because the EPA07 sensors share a supply, the procedure first checks whether related codes are present alongside SPN 3250/FMI 3, SPN 3246/FMI 3 and SPN 1172/FMI 3; if so, the turbocharger inlet air temperature sensor and pin 88 of the Motor Control Module (MCM) 120-pin connector are tested for a short to power or an open. The DOC inlet temperature sensor resistance is measured between pins 1 and 2 against the published table, and the connector voltage should read between 2.75 and 3.25 volts. Out-of-range sensors are replaced per Detroit Power Service Literature.

The full PDF is available in the DiagTechPro manuals library; a free account is required to download it.

3242 FMI 3 EPA07 — DOC Inlet Temperature Circuit Failed High 1 / 3
3242 FMI 3 EPA07 — DOC Inlet Temperature Circuit Failed High - preview page 1 of 3
3242 FMI 3 EPA07 — DOC Inlet Temperature Circuit Failed High - preview page 2 of 3
3242 FMI 3 EPA07 — DOC Inlet Temperature Circuit Failed High - page 3 is available after signing in
Free preview - 2 of 3 pages. Sign in to download the full PDF. Create a free account to download the full PDFNo credit card required · Instant download
This entry was posted in . Bookmark the permalink.
Telegram Telegram us WhatsApp WhatsApp us